Microlife BP3GX1-5X Review
Wide cut range cuff fits arms( 8.7"-16.5") ac adapter and batteries free- blood pressure tracking and analysis software.
- Gentle inflation technology optimizes comfort and time
- 99 memories for 2 users
- Advanced blood pressure averaging technology
- Irregular heartbeat detection and hypertension risk indicator
- Gentle inflation technology optimizes comfort and time
- 99 memories for 2 users
- Advanced blood pressure averaging technology
- Irregular heartbeat detection and hypertension risk indicator
Microlife BP3GX1-5X Hypertension risk indicator
The bars on the left-hand edge of the display show you the range within which the indicated blood pressure value lies. Depending on the position of the triangle indicator, the readout value is either within the normal(green), borderline (yellow) or danger (orange, dark orange) range.The classification is based on standards established by the National Institutes of Health JNC7, 2003
Microlife BP3GX1-5X Irregular heartbeat detector
The appearance of this symbol indicates that certain pulse irregularities were detected during the measurement. In this case, the result may deviate from your normal basal blood pressure – repeat the measurement. In most cases, this is no cause for concern. However, if the symbol appears on a regular basis (e.g., several times a week with measurements taken daily), we advise you to tell your doctor.Please show your doctor the following explanation:Information on frequent appearance of the irregular heartbeat symbol. This instrument is an oscillo metric blood pressure monitor device that also analyzes pulse frequency during measurement. The instrument is clinically tested.If pulse irregularities occur during the measurement, the irregular heartbeat symbol is displayed with the measurement.If the symbol appears frequently or if it suddenly appears more often than usual, we recommend the patient seek medical advice. The instrument does not replace a cardiac examination but serves to detect pulse irregularities at an early stage
Batteries almost discharged
When the batteries are approximately 75% used, the battery symbol will flash a few times as soon as the instrument is switched on (if at least one of the batter-ies still has some charge). Although the instrument will continue to measure reliably, you should obtain replacement batteries.Batteries discharged – replacements required. When the batteries are discharged, the battery symbol will appear, unblinking, as soon as the instrument is switched on. You cannot take any further measurements and must replace the batteries.1. Open the battery compartment on the bottom of the instrument.2. Replace the batteries – ensure they are correctly connected, as show non the symbols in the compartment.3. The memory retains all values although date and time (and possibly alsoset alarm times) must be reset – the year number will flash automatically after the batteries are replaced.4. To set date and time, follow the procedure described in Section 4.3.Note:Use four new, Long-Life 1.5 V AA batteries. Do not use batteries beyond their expiration date. If the monitor is not going to be used for a prolonged period, the batteries should be removed.